Mixing Dry Powder Controls
Operations
Mixing dry powders when there is the potential for aerosolization and release of nanomaterials into the workplace atmosphere
Controls
- Ventilated Laboratory Hood or local exhaust enclosure with HEPA* exhaust filtratration
- If an exhausted enclosure is not availiable, PPE should be used to minimize potential for respiratory, dermal and eye exposure
- Latex or nitrile clean room gloves
- Sealed goggles
- Wet cleaning of laboratory hood surfaces or local exhaust enclosure following conclusion of handling operations
Material Specific Controls
Created by MichaelGarner
.